Main duties:
Duties/Responsibilities:
* Perform final SAT (Site Acceptance Testing) & handover to customer of WP supplied transformers up to 132kV.
* Perform testing on transformers in the field during site refurbishments and relocation projects up to 132kV.
* Testing includes but is not limited to;
* Sweep Frequence Response Analysis (SFRA).
* Dissipation Factor & Capacitance (Tan Delta).
* Short Circuit Impedance.
* Exiting Current.
* Winding Resistance.
* Winding Ratio & Vector Check
* Insulation Resistance.
* CT Analysis.
* Protection Instrument Operational Testing.
* Complete SAT Reports to required standard and issue to customer.
* Offer support to general testing requirements, namely support with planning and customer interaction.
* You will ensure that all equipment is assembled and tested to the highest standard.
* You will read and understand mechanical and schematic drawings.
* You will be open to training and learning new methods.
* To work unsociable hours when required to meet demands, including site work as required.
Qualifications/Skills required for the role:
* GCSEs High school or equivalent;
* Candidate will have Electrical / Electronic City & Guilds Apprenticeship 2381, 2391 - as minimum qualification;
* Electrical Power Engineering qualification, minimum HNC level (Desirable – Depending on Experience);
* Broad knowledge of power engineering plant and equipment, i.e. Transformers & Reactors, HV & LV Switchgear, Cabling and HV & LV protection schemes.
* Hands-on experience of working within a mechanical/electrical engineering environment is essential.
* Electrical engineering experience.
* Transformer knowledge.
* Site based experience.
* Experience in Health & Safety and conducting risk assessments are essential.
* Full driving licence
* Site based qualification such as Safety Passport, PASMA, IPAF and more.
* DNO Authorisations (Can be trained – But must be willing to learn)