Social network you want to login/join with:
HVAP Data Centre Shift Technician – Slough, Slough
col-narrow-left
Client:
Phoenix Resourcing Services
Location:
Slough, United Kingdom
Job Category:
Other
-
EU work permit required:
Yes
col-narrow-right
Job Reference:
385eb1e3c1fb
Job Views:
2
Posted:
02.06.2025
Expiry Date:
17.07.2025
col-wide
Job Description:
Job reference: JO-2309-259010-1
Date posted: 26/04/2024
HV Data Centre Shift Technician
Location: Slough
Salary: £55,000
Hours – Continental Shift Pattern
Our client are a global data centre services organisation, steadily growing their presence, and have a requirement for multiple shift engineers tobe based at a newly built data centre facility in Slough. Working on a continental shift pattern, covering 12 hour days and nights, the role calls for experienced multi-skilled building services or data centre engineers to join and take responsibility for routine and reactive maintenance to electrical and mechanical systems in a highly critical environment. These sites are co-location, housing servers for blue chip, household name organisations and such is vital they maintain 100% uptime.
Guideline salary is up to £55,000 basic. Combined with opportunity for overtime and training, this is an exceptional opportunity to join a market leader in a booming sector.
Duties:
* Operate all M&E systems within the Data Centre in a competent, effective and efficient manner (including HV Electrical isolations/operations). Making recommendations for improvement and providing concise technical reports when required.
* Ensuring that all Specialist Sub Contractors visits are conducting works in line with approved Standard Operating
* Carrying out daily emergency callout tasks
* Completing logbooks and RAMS
* Able to apply a risk focused maintenance approach and operations of plant and systems in data centres/critical environments.
* Ensuring all critical client services, computer rooms, data networks, manufacturing and revenue earning services meet client requirements.
* Provide emergency response standby, call out. Escalate urgent issues. Respond to work interruptions, outages or emergencies consistent with the SLA.
* Support critical environment related technical audits as required and directed by line manager.
* Completion of records and logs required to demonstrate delivery of maintenance requirements.
* Control and supervise contractors when required.
* Emergency lighting testing
* All Electrical work including lighting, wiring, testing, alarm systems, BMS, lighting systems and Heat exchangers
* Engineers must be able to demonstrate appropriate knowledge of AHU, FCU, UPS, Generators, LV systems, which will include the ability to fault find.
* Evaluate and escalate any potential risks, with an assessment of impact, probable causes and mitigation opportunities.
* Actively contribute to continuous improvement of safe systems of work, ensuring compliance with relevant QHSE policy and procedures.
* Support the Data Centre Shift Leader in the day to day operational delivery of all planned, reactive, corrective and project related works.
Requirements:
* Trade trained with ideally 3 years’ experience in the building services
* City & Guilds Qualified Electrical Level 3.
* Critical site (Data Centre or Banking Sites)
* Good building services knowledge
* Ability to lead a team when under pressure, whilst remaining calm, clear thinking and able to deliver the required services to the client within given time constraints.
* Individuals who can demonstrate commitment and previous experience; but not meet all the required technical qualifications may be considered subject to Directors approval.
* Demonstrate a willingness to attend on and off site training for plant and systems this may require nights away from home.
#J-18808-Ljbffr